Description

On Advanced EPDR/EDR protection software versions v8.00.26.0000 to v8.00.26.0012, devices with Advanced Indicators of Attack (IOAs) enabled may experience performance problems. In some cases, the device may become temporarily unresponsive. Disabling the feature resolves the issue.

For information on how to determine the version of your Advanced EPDR/EDR product, see this article.

Workaround/Solution

A hotfix is available to resolve this issue.

To apply the hotfix on the affected endpoint:

  1. Download and save this hotfix file to the endpoint: hf-ker4036-performance-advanced-ioas.exe
  2. Double-click the downloaded file. The hotfix does not require a restart of the endpoint.
    However, under certain circumstances, you may be prompted to restart the computer to be fully applied. If you cannot restart the computer right away, select No when prompted.

Note: To install the unattended or silent version of the hotfix, click here. The hotfix is applied after the next system restart.

File Details

The hotfix updates these files:

File Name Location File Version Modified Date Hotfix to be included in future versions?
PSENAgent.dll C:\Program Files (x86)\Panda Security\WAC\PSENAgent.dll 4.24.0.1 5 November 2026 Yes
PSINEnAg.dll C:\Program Files (x86)\Panda Security\WAC\PSINEnAg.dll 4.24.0.4 5 November 2026 Yes
PSINEvAg.dll C:\Program Files (x86)\Panda Security\WAC\PSINEvAg.dll 4.24.0.2 5 November 2026 Yes
PSINUNC.dll C:\Program Files (x86)\Panda Security\WAC\PSINUNC.dll 4.24.0.1 5 November 2026 Yes
PSNCNotifMgr.dll C:\Program Files (x86)\Panda Security\WAC\PSNCNotifMgr.dll 4.24.0.1 5 November 2026 Yes
0x10000042.DAT (IOA.SIG) C:\Program Files (x86)\Panda Security\WAC\Cache\0x10000042.DAT 2.0.0.45 3 November 2026 Yes
0x10000043.DAT (TTP.SIG) C:\Program Files (x86)\Panda Security\WAC\Cache\0x10000043.DAT 2.0.0.34 3 November 2026 Yes
Verify Hotfix Application

To verify that the hotfix was successful, check the file version in the File Details section, or verify these values in the Windows Registry:

32-Bit Architecture 64-Bit Architecture
Registry Key Value Registry Key Value
HKEY_LOCAL_MACHINE\SOFTWARE\Panda Software\Setup\Hotfix history\HF_Performance_Advanced_IOAs Revision [REG_DWORD]

1

HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Panda Software\Setup\Hotfix history\HF_Performance_Advanced_IOAs Revision [REG_DWORD]

1

HKEY_LOCAL_MACHINE\SOFTWARE\Panda Software\Setup\Hotfix history\HF_Performance_Advanced_IOAs Result [REG_DWORD]

0 = Success
1 = Not Applied
2 = Error

9 = On Reboot

HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Panda Software\Setup\Hotfix history\HF_Performance_Advanced_IOAs Result [REG_DWORD]

0 = Success
1 = Not Applied
2 = Error

9 = On Reboot